Sanitary Fittings
Sanitary clamps are used to connect ferrules, gaskets, valves, fittings and tubing in hygienic process systems.
Applications
Clamps are commonly sourced together with ferrules, gaskets, valves and tube assemblies.
Clamp connections for sanitary transfer and cleaning systems.
Quick-disconnect sanitary assemblies for beverage process layouts.
Repeat clamp and gasket package sourcing for maintenance teams.
Sizes & Dimensions
Tri-clamps conform to DIN 32676 / ISO 2852 dimensional standards. Standard PN10 (10 bar) and heavy-duty PN16 (16 bar) configurations available.
| Size | DN | Clamp OD (mm) | Body Material | Wing Nut | Pressure Rating |
|---|---|---|---|---|---|
| ½" | DN15 | 50.5 | 304 / 316L | M8 | PN10 |
| ¾" | DN20 | 50.5 | 304 / 316L | M8 | PN10 |
| 1" | DN25 | 50.5 | 304 / 316L | M8 | PN10 |
| 1½" | DN40 | 64.0 | 304 / 316L | M8 | PN10 |
| 2" | DN50 | 77.5 | 304 / 316L | M8 | PN10 |
| 2½" | DN65 | 91.0 | 304 / 316L | M10 | PN10 |
| 3" | DN80 | 91.0 | 304 / 316L | M10 | PN10 |
| 4" | DN100 | 119.0 | 304 / 316L | M10 | PN10 |
Operating Conditions
Standard tri-clamps rated to PN10 (10 bar). Heavy-duty (double-pin or bolted) clamps extend rating to PN16 (16 bar) or higher.
Actual ratings depend on size, material and operating conditions. Confirm via RFQ for project-specific requirements.
Standards & Compliance
Full documentation packages available including MTR, 3.1 certificates, surface roughness reports and pressure test records.
Dimensional standard for tri-clamp fittings.
International standard for clamp connections.
Sanitary fittings standard for hygienic process.
Surface finish, materials and design for pharma/biotech.
Material specification for 304/316L bodies.
European hygienic engineering and design certification.
EU regulation on food-contact materials.
Chemical passivation treatments for stainless steel.
Product Variants
Multiple variants available to match your application requirements. Browse related products for complete process line coverage.

Standard tri-clamp with hinge pin and wing nut closure. Most common configuration for sanitary lines.
Request quote →
Two-pin design for higher pressure service and vibration resistance.
Request quote →
Bolted clamp for pressures above 10 bar or severe vibration service. Up to PN16.
Request quote →
Toggle-action clamps for frequent disassembly applications (sampling, batch processing).
Request quote →Technical Overview
Clamp selection depends on tube size, ferrule compatibility and service conditions.
| Requirement | Typical Information Needed |
|---|---|
| Product Type | Single-pin, double-pin or heavy-duty clamp by RFQ |
| Material Grade | 304 / 316L stainless steel |
| Connection | Tri-clamp sanitary ferrule compatibility |
| Size | Nominal sanitary tube / ferrule size |
| Documentation | MTR / QC by RFQ |
Include size, material, clamp style, quantity and related gasket/ferrule references.
Material certificates, finish notes, inspection requirements, heat traceability and supplier documentation can be included in the quotation package.
Send clamp size, quantity, material and related ferrule/gasket requirements.
Download the product datasheet for technical specifications, dimensional references, material data, applicable standards and RFQ guidance. Suitable for procurement, engineering review and project documentation.
Common Questions
Engineering and procurement questions we hear most often. For project-specific guidance, send your application details via RFQ.
304 clamps are standard for general sanitary service. 316L clamps have superior corrosion resistance, especially with chloride exposure or aggressive CIP chemicals.
For dairy with aggressive caustic cleaning, 316L is recommended for clamp durability. For pharma/biotech requiring 316L throughout, specify with order.
Standard torque is 5–7 N·m for M8 wing nuts. Over-tightening crushes gasket and reduces seal life — finger-tight plus quarter turn is typical practical guide.
For high-pressure service, use calibrated torque wrench. For vibration service, specify bolted (not wing-nut) clamps to prevent loosening.
Single-pin clamps are standard for most sanitary applications (PN10). Double-pin clamps provide vibration resistance and slightly higher pressure capability.
For pumped lines with vibration, mixers, or rotating equipment, specify double-pin. For static lines and moderate pressure, single-pin is sufficient.
PN10 = 10 bar maximum working pressure (single-pin standard). PN16 = 16 bar (bolted heavy-duty clamps only).
Most sanitary lines operate at 3-6 bar, well within PN10. For high-pressure CIP, pump discharge, or steam lines, specify PN16 with bolted clamps.
Yes — stainless steel clamps are reusable as long as no damage, deformation, or stress cracking is visible. Inspect at each disassembly.
Replace if you see: bent pin, worn wing nut threads, surface cracks, deformed band. Replacement is inexpensive and prevents joint failure.
Yes — 304 and 316L stainless clamps are fully autoclave-compatible (121°C steam). However, the gasket material limits practical autoclave use to EPDM/silicone/PTFE.
For continuous SIP service, specify clamp material to match gasket. 316L recommended for repeated thermal cycling to prevent stress corrosion.
Standard: 3.1 MTR (material certificate) with heat number traceability. Optional: dimensional inspection report, surface roughness, passivation certificate.
For pharma/biotech, request full BPE documentation including ferrite content and surface finish report (Ra ≤ 0.8 μm mill or 0.38 μm EP).